Researchers found that spontaneous infraslow hemodynamic oscillations during sleep coordinate spatially structured, directional CSF flow in both ventricular and subarachnoid compartments.

Researchers found that spontaneous infraslow hemodynamic oscillations during sleep coordinate spatially structured, directional CSF flow in both ventricular and subarachnoid compartments.
đź§Ş #NewArticle: Particle transport in intracranial aneurysms: a non-dimensional discrete element model study.
🤝 Colaboración: iMATUS, CITMAga, IDIS, CIBERCV e SERGAS.
🔗 Ler máis:
www.sciencedirect.com/science/arti...
#Biomechanics #Hemodynamics #Biomaterials
In 133 pazienti ICU trattati con landiololo, l’intolleranza non era bradicardia: era ipotensione o aumento dei vasopressori, quasi sempre entro 6 h. Pressione diastolica bassa e vasopressori in corso possono segnalare scarsa riserva emodinamica. #Hemodynamics #CriticalCare
https://doi.org/10.1186/s1
In 133 ICU patients given landiolol, intolerance was not bradycardia: it was hypotension or rising vasopressor need, usually within 6 h. Low diastolic pressure and vasopressor dependence may signal limited hemodynamic reserve. #Hemodynamics #CriticalCare
https://doi.org/10.1186/s13054-026-06342-w
CHEM-FACT: a 30 min l’ossigenazione cerebrale media era simile, ma con fenilefrina il calo era del 9% maggiore vs efedrina mentre aumentava la domanda metabolica. Il segnale era nella traiettoria. #Hemodynamics #Anesthesia
https://doi.org/10.1097/ALN.0000000000006239
CHEM-FACT shows why averages can mislead: mean cerebral oxygenation at 30 min was similar, yet phenylephrine caused a 9% greater decline than ephedrine while metabolic demand rose. The trajectory carried the signal. #Hemodynamics #Anesthesia
https://doi.org/10.1097/ALN.0000000000006239
Durante un preload challenge, la capnografia può diventare un monitor di flusso: le variazioni dell’EtCO₂ predicevano la fluid responsiveness con AUC ~0,87. L’informazione è nella risposta alla manovra, non nell’EtCO₂ assoluta. #Hemodynamics
https://doi.org/10.1186/s13054-026-06320-2
During a preload challenge, capnography may become a flow monitor: dynamic EtCOâ‚‚ changes predicted fluid responsiveness with AUC ~0.87. The information lies in the response to the maneuver, not the absolute EtCOâ‚‚. #Hemodynamics
https://doi.org/10.1186/s13054-026-06320-2
Un basso perfusion index intraoperatorio era associato a iperlattatemia a fine intervento, ma con discriminazione modesta (AUC 0,66). Segnale utile, target debole. #Hemodynamics
https://doi.org/10.1186/s12871-026-04241-9
A low intraoperative perfusion index was associated with end-of-surgery hyperlactatemia, but discrimination was modest (AUC 0.66). Useful signal, poor standalone target. #Hemodynamics
https://doi.org/10.1186/s12871-026-04241-9
Ripristinare il flusso carotideo non ha migliorato la cognizione, neppure con emodinamica cerebrale compromessa. Un deficit di flusso non è necessariamente la causa reversibile della disfunzione. Trattare il meccanismo, non solo la variabile. #Hemodynamics
https://doi.org/10.1001/jama.2026.13384
Restoring carotid flow did not improve cognition, even with impaired cerebral hemodynamics. A measured flow deficit can describe physiology without proving it is the reversible cause of dysfunction. Treat the mechanism, not just the variable. #Hemodynamics
https://doi.org/10.1001/jama.2026.13384
In VA-ECMO la PEEP cambiava poco dopo la cannulazione, nonostante la fisiologia mutata. PEEP più alta non mostrava danno emodinamico né migliore weaning. Il segnale è inerzia terapeutica: la PEEP va rivalutata come intervento cardiovascolare. #Hemodynamics
https://doi.org/10.1186/s13054-026-06332-y
On VA-ECMO, PEEP was barely changed after cannulation despite altered physiology. Higher PEEP showed no clear hemodynamic harm or better weaning. The signal is therapeutic inertia: PEEP should be re-evaluated as a cardiovascular intervention. #Hemodynamics
https://doi.org/10.1186/s13054-026-06332-y
L’HPI può ridurre l’ipotensione, ma i trial raccontano una storia più scomoda: più trattamento, non trattamento migliore. Finora nessun trial ha mostrato un beneficio convincente. L’ipotensione è un marker, non un target terapeutico. #Hemodynamics
https://doi.org/10.1097/ALN.0000000000006367
HPI may reduce hypotension, but the trials tell a harder story: more treatment, not clearly better treatment. So far, no trial has shown a convincing patient-centered benefit. Hypotension is a marker, not a treatment target in itself. #Hemodynamics
https://doi.org/10.1097/ALN.0000000000006367
Aumentare la PAM non significa migliorare l’emodinamica. Nello shock settico, lo stesso aumento da ~65 a 85 mmHg ha aumentato il flusso in alcuni pazienti e lo ha ridotto in altri. Un target pressorio senza risposta di flusso è incompleto. #Hemodynamics
Raising MAP is not the same as improving hemodynamics. In septic shock, the same rise from ~65 to 85 mmHg increased flow in some patients and reduced it in others. A pressure target without a flow response is an incomplete target. #Hemodynamics
GA-Targets (2026): piĂą danno renale e aritmie con target di PAM 80 vs 60 mmHg. Ma era uno studio di fattibilitĂ : un segnale da verificare, non un target per tutti. #Hemodynamics #Anesthesia
GA-Targets (2026): more kidney injury and arrhythmias at MAP 80 vs 60 mmHg. But this was a feasibility trial: a signal to test, not a universal target. #Hemodynamics #Anesthesia